Technicial Specifications
Generator Set Specifications
Engine Specifications
Generator Set Dimensions
Standby Rating | 3000 kVA (3100 kVA without fan) |
Prime Power Rating | 2750 kVA (2850 kVA without fan) |
Emissions/Fuel Strategy | Low Fuel Consumption |
Voltage | 380 to 11000 volts |
Frequency | 50 Hz |
Speed | 1500 rpm |
Duty Cycle | Standby, Mission Critical, Prime |
Maximum Rating | 3000 kVA (3100 kVA without fan) |
Minimum Rating | 2750 kVA (2850 kVA without fan) |
Engine Model | 3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel |
Bore | 170 mm |
Stroke | 215 mm |
Displacement | 78.1 l |
Compression Ratio | 14:01 |
Aspiration | TA |
Fuel System | Electronic unit injection |
Governor Type | Adem™ A5 |
Length - Maximum | 7538 mm |
Width - Maximum | 2216 mm |
Height - Maximum | 3391 mm |
Dry Weight - Genset (maximum) | 19750 kg |
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- EU Declaration of Conformity
- EU Declaration of Incorporation
- Eurasian Conformity (EAC)
- Telecommunication Lab of China
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standard Equipment
-
Air Inlet System
- Air cleaner
- Single element canister type with service indicator
-
Control Panel
- Environmental sealed front face
- Warning/shutdown with common LED indication of shutdowns for:
- Overspeed
- RPM
- Generator phase sequence
- Emergency stop pushbutton
- Digital indication for:
- Text alarm/event descriptions
- 2 Programmable digital outputs
- Reverse reactive power (kVAr) (32RV)
- Reverse power (kW) (32)
- Failure to start (overcrank)
- Panel lights
- Speed adjust
- Oil pressure (psi, kPa or bar)
- Low coolant level
- Generator mounted - rear facing
- Over/under frequency (81 o/u)
- Lamp test
- True RMS AC metering, 3-phase, +/-2% accuracy
- Low coolant temperature
- Power factor (per phase & average)
- Frequency (Hz)
- Overcurrent (50/51)
- High coolant temperature
- DC volts
- 6 Programmable digital inputs
- Coolant temperature
- 24 Volt DC operation
- Amps (per phase & average)
- Emergency stop
- Alarm acknowledge
- Programmable protective relaying functions:
- 2 Programmable relay outputs (Form C)
- EMCP 4.2B
- Serial annunciator module data link
- Controls:
- kW-hr (total)
- kW (per phase, average & percent)
- Engine cool-down timer
- Operating hours
- EMCP 4 Genset controller
- Volts (L-L & L-N)
- Engine cycle crank
- Communications:
- kVAr (per phase, average & percent)
- EMCP4.2B controller includes:
- Customer data link (Modbus RTU)
- Over/under voltage (27/59)
- Low oil pressure
- kVA (per phase, average & percent)
- kVAr-hr (total)
- 4 Programmable relay outputs (Form A)
- Accessory module data link
-
Exhaust
- Exhaust flange outlet
-
Fuel
- Primary fuel filter with integral water separator
-
Generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
-
Power Termination
- Busbar
-
Starting/Charging
- Heavy duty starting system
- Charging alternator
-
Cooling System
- Caterpillar extended life coolant
- Radiator fan and fan drive
- Fan and belt guards
- JWAC
- Coolant drain line with valve
- Coolant level sensors
-
Cooling
- Package mounted radiator
-
Exhaust System
- Dry exhaust manifold
- Flanged faced outlet(s)
-
Fuel System
- Secondary fuel filters
- Fuel priming pump
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines - shipped loose
-
Generators and Attachments
- Internal excitation (IE)
- 6 Lead
- Busbar connections, top center mounted, top cable entry
- IEC standard hole pattern
- Random wound
- 3 Phase brushless, Salient pole
- Winding temperature detectors
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby).
- Generator set packages include Caterpillar's digital voltage regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
-
Governing System
- ADEM III
-
Literature
- Parts book
-
Lube System
- Lubricating oil
- Oil filter, filler and dipstick
- Fumes disposal
- Oil drain lines and valve
- Gear type lube oil pump
- Integral lube Oil cooler
-
Mounting System
- Rubber anti-vibration mounts - shipped loose
- Rails - Engine/generator/radiator mounting
-
Starting / Charging System
- Battery and battery rack w/cables
- 24 Volt electric starting motor
- Battery disconnect switch
-
General
- Right hand servicing
- Paint - Caterpillar yellow with high gloss black rails & radiator
- Flywheel and flywheel housing-SAE No. 00
- SAE standard rotation
Optional Equipment
-
Air Inlet System
- Air inlet protection
- Heavy duty air cleaners
- Remote air inlet adapters
- Dual element air cleaners
-
Circuit breakers
- Cable entry options
- Control packaging for enclosures
- Optional busbar power connections
- EMAX breakers
- Load take off; IEC standard hole
- Center posts busbars
- Trip units
-
Power Termination
- Circuit breakers, IEC compliant
-
Control Panels
- External box clips
- Local and remote monitoring
- Busbar connections
- Governors
- Generator temperature monitoring
- Auxiliary box
- Voltage raise/lower switch
- EMCP 4.3, EMCP 4.4
- EMAX breaker connections
- Language options
- Remote speed adjust
- Annunciator modules
- Customer interface options
- Vandal proof panel door
-
Cooling System
- Optional Serpentine radiators
- Water level switch gauges
- Heat exchangers
- Radiator duct flanges
-
European Certifications
- EU Declaration of Conformity
-
Exhaust System
- Mufflers
- Through wall installation kit
- Flexible fittings
- Muffler mounting kits
-
Fuel System
- Fuel coolers
- Primary fuel filter
-
Generators and attachments
- 3 Phase, Random wound, Internal excitation (IE)
- Internal excitation (IE)
- Random wound
- Pitch: 0.6667
- Optional generators
- Number of leads: 6
-
3 Phase, 380 / 400 / 415 / 3300 / 6600 / 10000 / 10500 / 11000 volt
-
Instrumentation
- Thermocouples
- Pyrometers and thermocouples
-
Lube System
- Manual prelube sump pumps
- Oil level regulator
- Electric prelube pumps
-
Mounting System
- Spring type vibration isolators
- IBC vibration isolators
-
Protection System
- Explosion relief valves
-
Special Tests / Reports
- PGS Test report @ 0.8 power factor
- CSA test and certification
- Neutral ground certificate
- PGS Test report @ 1.0 power factor
- IBC seismic Certification
-
Starting / Charging System
- Jacket water heaters
- ETHER starting aids
- Dual 24 volt electric starting motors
- 24 Volt battery set - Dry
- Charging alternators - 50 Amp
- 10 and 20 Amp Battery chargers
-
General
- Engine barring group