Leasing calculator - will allow you to calculate the cost of your monthly payment. Leasing Calculator
Parts online
 
 
 
 
 

DE605 GC (50 Hz)

DE605 GC (50 Hz)

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Maximum Rating 605 kVA
Minimum Rating 605 kVA
Emissions/Fuel Strategy Non Regulated

Technicial Specifications

Generator Set Specifications
Maximum Rating 605 kVA
Minimum Rating 605 kVA
Emissions/Fuel Strategy Non Regulated
Voltage 380 to 415 Volts
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby
Engine Specifications
Engine Model C15 In-line 6, 4-cycle diesel
Bore 137 mm
Stroke 171 mm
Displacement 15.2 l
Compression Ratio 16.1:1
Aspiration Turbocharged Air-to-Air Aftercooled
Fuel System EUI
Governor Type Adem™A4
Generator Set Dimensions
Length - Maximum 3328 mm
Width - Maximum 1540 mm
Height - Maximum 2187 mm
Dry Weight - Genset (maximum) 3683 kg

Advantages and Features

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

A-Frame Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

GCCP 1.3 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

One Safe Source

  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Standard Equipment

  • Engine
    • Cat® C15 Inline 6 cylinder, 4 stroke diesel
  • Control Panels
    • GCCP 1.1
  • Air Inlet
    • Air cleaner
  • Governor
    • Mechanical governor
  • Alternator
    • A Frame standard alternator
  • Cooling
    • Package mounted radiator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Cooling System
    • Caterpillar extended life coolant
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
  • Electrical Options
    • 3 Pole Circuit breaker
    • Neutral earth link
    • 24 Volt battery with rack and cables
  • Fuel
    • Secondary fuel filters
    • Fuel priming pump
    • Primary fuel filter with integral water separator
  • Air inlet system
    • Air cleaner; light duty with disposable element
  • Generator
    • IP23 Protection
    • Matched to the performance and output characteristics of Cat engines
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
  • Lube system
    • Lubricating oil
    • Oil drain line with valve
  • Mounting system
    • Captive linear vibration isolators
    • Lifting provision and drag points
  • General
    • Engine and alternator pre paint, Caterpillar yellow
    • Engine and alternator pre paint, Caterpillar yellow
  • Power Termination
    • Busbar
  • Generator and Attachments
    • Power center, IP22
    • Segregated low voltage (AC/DC) wiring panel
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Mounting
    • Rubber vibration isolators
  • Governing System
    • Cat electronic governor (ADEM A4).
  • Lube System
    • Oil cooler
    • Oil drain valves
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Optional Equipment

  • Exhaust
    • Industrial, residential, critical mufflers
  • Control panel
    • Speed and Voltage adjust potentiometers
    • PLG 4G/3G/Ethernet
    • Annunciator
    • Emergency E-Stop
  • Enclosure
    • Cat GC enclosure
  • Generator
    • Anti-condensation heater
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Oversize and premium generators
  • Electrical Options
    • 4 Pole Circuit breaker
    • Auxiliary contacts
    • Padlockable circuit breaker
    • Battery charger
    • Wet battery
  • Power Termination
    • Circuit breakers, IEC compliant
    • Circuit breakers, UL listed
  • Alternator
    • Space heater
    • AVR
  • Fuel System
    • Dual wall 8 hour fuel tank
    • Single wall 8 hour fuel tank with spill containment
    • Low fuel level shutdown
    • Low and high fuel level alarms
    • Manual fuel transfer pump
    • Fuel transfer system controls
    • Dual wall fuel tank base
  • Generator and Attachments
    • Oversize A Frame generator
    • LC frame CIP generator
    • Permanent magnet excitation (PMG) generator
    • Space heaters
    • Ingress protection
    • LC frame generator
    • A Frame generator - IP21 Protection
    • CIP A Frame generator
    • Oversize LC frame generator
  • Starting/Charging
    • Charging alternator
    • Jacket water heater
    • Battery chargers
    • Oversize batteries
    • Heavy duty starting system
    • 24 Volt battery with rack and cables
  • Air inlet system
    • Single stage air filter
    • Dual element air filter
  • Certifications
    • EU Certificate of Conformance (CE)
    • EAC Certification
  • General
    • Automatic transfer switches (ATS)
    • EEC Declaration of Conformity
    • Integral & sub-base UL listed dual wall fuel tanks
    • Single or dual wall sub-base fuel tanks
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
    • CSA Certification
    • UL 2200 package
    • The following options are based on regional and product configuration:
    • Single or dual wall integral fuel tanks
    • EU Certificate of Conformance (CE)
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • Narrow, wide or skid base
  • Extended service coverage
    • 3, 4, 5 and 10 Years
  • Enclosures
    • High ambient sound attenuated enclosures
  • Exhaust System
    • Industrial silencer
    • 10 dBA Attenuation silencer
    • Manifold and turbocharger guards
    • End in/end out mufflers - 10, 25 and 35 dBA attenuation
    • Flexible exhaust fittings
    • 6 and 8 inch elbow kit
    • 6 and 8 inch flange GP
    • Engine mounted muffler
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base - replaces standard fuel tank base
  • Special Test / Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • 5 Amp single Battery charger
    • Battery disconnect switch
    • Jacket water heater