Technicial Specifications
Standby Rating | 3500/3250/3000 kVA |
Prime Power Rating | 3175/2950/2725 kVA |
Emissions/Fuel Strategy | U.S. EPA Cert. Tier 2 / Low NOx |
Voltage | 380 to 11000 volts |
Frequency | 50 Hz |
Speed | 1500 rpm |
Duty Cycle | Standby, Mission Critical, Prime |
Maximum Rating | 3500 kVA |
Minimum Rating | 2725 kVA |
Engine Model | 3516E, V-16, 4-Stroke Water-Cooled Diesel |
Bore | 170 mm |
Stroke | 215 mm |
Displacement | 78.1 l |
Compression Ratio | 14.0:1 |
Aspiration | ATAAC |
Fuel System | Electronic Unit Injection |
Governor Type | Adem™ A5 |
Length - Minimum | 7685 mm |
Length - Maximum | 7785 mm |
Width - Maximum | 2612 mm |
Height - Maximum | 3342 mm |
Dry Weight - Genset (minimum) | 20380 kg |
Dry Weight - Genset (maximum) | 20707 kg |
Advantages and Features
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
Cat ECS Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50�C (122�F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
- EU Declaration of Conformity
- EU Declaration of Incorporation
- Eurasian Conformity (EAC)
One Safe Source
- Components used in the generator set are selected at the design stage to provide optimum package performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Standard Equipment
-
Air Inlet System
- Air cleaner; single element canister type
-
Control System
- Generator set packages include:
- Emergency stop pushbutton
- 24 Volt DC operation
- KVAR / PF modes
- IVR includes reactive droop capability
- Cat ECS 100
- Text alarm/event descriptions
- Generator mounted - rear facing
- Environmental sealed front face
- RFI suppression
- 3 Phase voltage sensing
- Caterpillar's voltage regulator
- Min / max exciter
- Limiter and exciter diode monitor
- Controls:
- Speed adjust
- Auto/start/stop control
- Engine cycle crank
- Engine cool
- Alarm acknowledge
- PLC functionality
- Customizable screens
- Lamp test
- Load histogram feature
- Generator phase sequence
- 1 Programmable relay outputs (Form C)
- RPM
- High coolant temperature
- Accessory module data link
- Low coolant level
- Number of I/O varies on options selected
- Digital indication for:
- Reverse power (kW) (32)
- Reverse reactive power (kVAr) (32RV)
- Overcurrent (50/51)
- 6 Customer programmable digital inputs
- 3 Analog inputs
- Serial annunciator module data link
- Over/under frequency (81 o/u)
- Low coolant temperature
- +/- 2% accuracy
- Programmable protective relaying functions:
- Failure to start (overcrank)
- 4 Programmable relay outputs (Form A)
- Cat connect
- Over/under voltage (27/59)
- 1 Programmable digital outputs
- 0 True RMS AC metering
- 3 Phase
- Communications:
- Overspeed
- DC volts
- Operating hours
- Coolant temperature
- Oil pressure (psi, kPa or bar)
- Volts (L-L & L-N)
- Power factor (per phase & average)
- Frequency (Hz)
- Amps (per phase & average)
- kW (per phase, average & percent)
- kVA (per phase, average & percent)
- kVAr (per phase, average & percent)
- Low oil pressure
- kVAr-hr (total)
- kW-hr (total)
- Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
-
Cooling System
- ATAAC - 3516E package radiators shipped installed
- Certified standard PGS provided
-
Exhaust System
- Dry exhaust manifold
- Flanged faced outlet(s)
-
Fuel System
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
- Flexible fuel lines - shipped loose
-
General
- SAE standard rotation
- Flywheel and flywheel housing - SAE No. 00
- Right hand servicing
- Caterpillar yellow with high gloss black rails and radiator
-
Generator and Attachments
- Anti-condensation space heater
- Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
- 3 Phase brushless, Salient pole
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Winding temperature detectors
- High voltage:
- Medium voltage:
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
- NEMA standard hole pattern
- 6 Lead
- Permanent magnet excitation (PMG)
- Form wound
- Busbar connections, right side extension box, bottom cable entry
-
Governing System
- ADEM A5
-
Literature
- Parts book
- Operation & Maintenance Manual
-
Lubrication System
- Gear type lube oil pump
- Lubricating oil
- Oil filter, filler and dipstick
- Integral lube oil cool
- Oil drain lines and valve
- Fumes disposal
-
Mounting System
- Rails - Engine/generator/radiator mounting
- Anti-vibration mounts (shipped loose)
- Rubber anti-vibration mounts - shipped loose
-
Starting System
- 24 Volt electric starting motor
- 45 Amp Charging alternator
- Battery and battery rack w/cables
- Battery disconnect switch
Optional Equipment
-
Control System
- EMCP 4.4
-
Air Inlet System
- Single element filter
- Dual element air cleaner
-
Cooling System
- Standard ambient ATAAC radiators
- Water level switch gauges
- Optional installed ATAAC radiators
- Coolant
- Optional installed radiators
- Standard ambient radiators
-
Crankcase System
- Ventilation system
- Explosion relief valves
- No explosion relief valves
-
Exhaust System
- Y Adapters
-
Fuel System
- Primary fuel filter
- Fuel priming pumps (Tier 4) - Manual or electric
-
General
- US aid emblem
- Special paint (Colors other than Caterpillar yellow or high performance paints)
-
Generators and Attachments
- Thermostat for space heater
- Alternator air cleaner
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Generator conversion
- Space heater
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
-
Instrumentation
- Pyrometer and thermocouples
-
Lubrication System
- Lube oil in standard sump
- Prelube pumps
- Oil level regulator
-
Mounting System
- Puck style low efficiency isolators
- Spring type vibration isolators
- IBC vibration isolators
-
Power Connections
- Neutral ground connections
- Center post busbars
- Right side power connections
-
Special Tests / Reports
- Generator set fuel consumption test
- Torsional vibration analysis reports
- PGS Test report @ 0.8 power factor
- IBC Certification
- PGS Test report @ 1.0 power factor
- Canadian Standards Association certification
- Standard engine test charge
- Generator test report
- Fuel consumption test
- OSHPD Certification
-
Starting and Charging
- Air pressure regulator
- Jacket water heaters
- Air starting motors
- 24 Volt battery set - Dry
- Starter cover
- Engine barring device
- 10, 20, 35 and 50 Amp Battery chargers
- Electric starting motors
-
Extended Service Coverage
- Platinum, Gold and Silver coverage